World Class Manufacturer of Custom Switches, Connectors & Assemblies
Certifications
Search Catalog
      GO   
 All Categories    Top Actuated Maintained Slide Switches
All Categories > Switches > Slide Switches > Standard Slide Switches > Top Actuated Maintained Slide Switches > Item # GF-326-0000  
Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

Item # GF-326-0000, GF - Series Double Pole/Double Throw (with Detent) Standard Slide Switch







Check Distributor Stock  · Specifications  · Materials  · Performance Standards  · Care in Switch Installation

Check Distributor Stock

Check Distibutor Stock

DIGI-KEY


Specifications

Circuitry

DPDT

Switch Function

ON-ON

Electrical Ratings

0.5 A @ 125 VDC
3 A @ 125 VAC

Actuator Style & Color

Flat Knurled - Black

Actuator Legend

None

Actuator Height

0.344 in.

Actuator Options

Standard Actuator Options

Topper Options

Standard Actuator Topper Options

Mounting

Mounting Ears

Mounting Options

Mounting Options

Terminal

Solder

Termination Options

Slide Switch Terminal Options

Solder Shield

Vulcanized Fiber Shield 0.020" thick that fits over the switch terminals is also available

Listing Agency
(Consult drawing or factory for specific rating)1

Compliance

1 Due to ongoing advancements, additional agency certifications may be available, contact us for more information.


Materials

Button Material

Nylon 6/6

Housing

Zinc Plated Cold Rolled Steel

Moving Contact

Copper Alloy

Moving Contact Plating

Silver is standard. Gold plating is an option, consult factory.

Moving Contact Spring

Beryllium Copper or
Phosphor Bronze

Terminals

Copper Alloy

Terminal Plating

Silver is standard. Gold plating is an option, consult factory.

Terminal Board

NEMA Grade XP Phenolic Laminate

Note

Other materials to suit your application are available if volume is sufficient. Contact us for more information.


Performance Standards
CW switches are designed to perform to the standards listed when operated within ambient conditions detailed below:
Operating Temperature - 105ºC maximum, -20ºC minimum.
Relative Humidity - Switches will be operable and insulation resistance shall be greater than 100 megohms if allowed to dry for 100 hours at room temperature of 25ºC and after exposure for one hour in an atmosphere having 95% relative humidity and a temperature of 50ºC
High Voltage Breakdown - Minimum of 1000 volts RMS 60 Hz for one minute between parts of opposite polarity.
Contact Resistance - Less than 0.01 ohm at 20 milliamperes DC.
Life Cycling (No Load) - Switches will be operative after 10,000 (minimum) cycles at the rate of 10 cycles per minute.
Life Cycling (Load) - Switches will be operative after 6000 (minimum) cycles at the rate of 10 cycles per minute at rated load



Care in Switch Installation
CW switches will perform properly if they are installed and used properly. Causes for failure often encountered in the field that are the responsibility of the user are:
  1. Removal of factory applied lubricants from switch contacts and moving parts.
  2. Introduction of foreign material into switching mechanism...flux, solder cleaning materials, potting compounds.
  3. Restriction of movement of switch button.
  4. Excessive heat often introduced while soldering.
  5. Switching loads in excess of rating.
Manufacturing Engineers are cautioned to avoid misusing switches and resultant switch failures.



 DOWNLOADS 

Slide Switch Schematic
(PDF, 645KB)

GF-326-0000_2D DRAWING
(PDF, 54KB)

GF-326-0000_3D MODEL
(STP, 1141KB)


CW INDUSTRIES
130 James Way - Southampton, PA 18966
215-355-7080 | fax: 215-355-1088 | info@cwind.com
Legal | Sitemap | Catalog Index
© 2011 CW Industries - All Rights Reserved