Item # GRS-2013A-2500, 2000 Series Center-Off Full Size Rocker Switches






Check Distributor Stock  · Specifications  · Materials  · Operating Standards

Check Distributor Stock

Check Distributor Stock

DIGI-KEY
MOUSER


Specifications

Circuitry

SPDT

Switch Function

ON-OFF-ON

Electrical Ratings1

10 A @ 14 V (T)
12 A @ 250 VAC

16 A @ 125 VAC

3/4 HP @ 125-250 VAC

Temperature Rating

+65 Max. Degress C

Panel Opening

1.125 X 0.550 in
28.58 X 13.97
mm

Acceptable Panel Thickness

0.025 - 0.180 in
0.64 - 4.57
mm

Mounting

No hardware or tools needed; self locks into one of the two available panel opening options.

Specify - GRSX-2000 Series - 2000 for 0.550 X 1.125 in. panel opening.
Specify - GRSX-2000 Series - 3000 for 0.480 X 1.072 in. panel opening.

CAUTION: Burr direction must be away from the direction of insertion.

Mounting Polarization

No

Actuator Color

Black

Actuator Legend

None

Illumination

Non Illuminated

Housing Color

Black

Insulating Barriers

( _ ) Between Terminals   ( X ) No Barriers

Terminals

(X) 0.250 x 0.032in.      6.35 x 0.81mm.   Quick Connect
(_) 0.187 x 0.032in.       4.75 x 0.81mm.   Quick Connect

Listing Agency
(Consult drawing or factory for specific rating)2

Compliance

1 Additional ratings may be available, contact us for more information.
2 Due to ongoing advancements, additional agency certifications may be available, contact us for more information.


Materials

Rocker Knob

Nylon 94V-2

Housing

Nylon 94V-2

Terminal & Moving Contact

Copper Alloy or
Copper Alloy Silver Plated


Operating Standards
Endurance:
100,000 cycles, no load, minimum
25,000 cycles at rated load minimum
Contact Resistance:
Less than 0.01 Ω at 10 mA
Operating Temperature:
From -20ºC to 105ºC maximum.
Consult factory for higher or lower temperature ranges
High Voltage Dielectric Withstanding Voltage:
2,500 V, 60 Hz for 1 minute between mounting surface and circuit connections (min.)
Relative Humidity:
Insulation resistance > 103 MΩ after 100 hours at 95% R.H. and 50ºC followed by 1 hour dry at ambient room conditions

Operating Standards described herein are general specifications that vary depending on the switch construction specified and end application. Contact us for specifications for specific models. Specifications subject to change without notice.