CW INDUSTRIES
130 James Way
Southampton, PA 18966
Phone: 215-355-7080 • Fax: 215-355-1088
Email: info@cwind.com Website: http://www.cwind.com
All Categories > Switches > Rocker Switches > Miniature Rocker Switches > 4000 Series Miniature Rocker Switches > 4000 Series Maintained Action Miniature Rocker Switches > Item # GRS-4022-0003  


Item # GRS-4022-0003, 4000 Series Maintained Action Miniature Rocker Switches






Check Distributor Stock  · Specifications  · Materials  · Operating Standards

Check Distributor Stock

Check Distributor Stock

DIGI-KEY


Specifications

Circuitry

DPDT

Switch Function

ON-ON

Electrical Ratings1

10 (4) 250~µ T 85°
10 A @ 14 V T

16 A @ 125-250 VAC

3 A @ 125 V L

3/4 HP @ 125-250 VAC

Temperature Rating

+65 Max. Degrees C

Panel Opening

0.508 x 0.756 in
12.90 x 19.20
mm

Acceptable Panel Thickness

0.050 - 0.150 in
1.27 - 3.81
mm

Mounting

Self locks without hardware when inserted into a 0.756" (19.20 mm) x 0.508" (12.90 mm) panel cutout. Acceptable panel thickness range is from 0.050" (1.27 mm) to 0.150" (3.81 mm).

CAUTION: Burr direction must be away from the direction of insertion.

Mounting Polarization

None

Actuator Color

Black

Actuator Legend

I/O - Horizontal

Illumination

Non Illuminated

Housing Color

Black

Insulating Barriers

(X) Between Poles     ( _ ) Between Terminals     ( _ ) No Barriers

Terminal

(X) 0.187 x 0.032in.      4.75 x 0.81mm.  Quick Connect
(_) 0.187 x 0.020in.       4.75 x 0.51mm.   Quick Connect
(_) 0.110 x 0.032in.       2.79 x 0.81mm.    Quick Connect
(_) 0.110 x 0.032in.       2.79 x 0.81mm.    Solder Terminal

Contact Action

Sliding with Self Cleaning Contacts

Listing Agency
(Consult drawing or factory for specific rating)2

Compliance

1 All ratings are on a load per pole, opposite polarity basis. Additional ratings may be available, contact us for more information.
Switches marked µ are acceptable for use as power switches provided there is a plug disconnect or a switch with open contact gaps of 3 mm minimum.
2 Due to ongoing advancements, additional agency certifications may be available, contact us for more information.


Materials

Rocker Knob

Nylon 94V-2

Housing

Nylon 94V-2

Terminal & Moving Contact

Copper Alloy or
Copper Alloy Silver Plated


Operating Standards
Endurance:
100,000 cycles, no load, minimum
25,000 cycles at rated load minimum up to 16 A @ 125 VAC
10,000 cycles at rated load minimum 16 A @ 250 VAC
Contact Resistance:
Less than 0.01 Ω at 10 mA (Initial)
Operating Temperature:
From -20ºC to 105ºC maximum.
Consult factory for higher or lower temperature ranges.
High Voltage Dielectric Withstanding Voltage:
2,500 V, 60 Hz for 1 minute between mounting surface and circuit connections
Humidity:
Insulation resistance > 103 MΩ after 100 hours at 95% R.H. and 50ºC followed by 1 hour dry at ambient room conditions

Operating Standards described herein are general specifications that vary depending on the switch construction specified and end application. Contact us for specifications for specific models. Specifications subject to change without notice.




Print Back